| Interface | |
| Interface | Profibus DP | 
| Profile | DPV0, DPV1 and DPV2 Class 2 (EN50170 + EN50254) | 
| Diagnostics | Memory | 
| Manual Functions | Address selector switch 0-99 and terminal resistor (with connection cap) | 
| Features | Round Axis | 
| Transmission Rate | ≤12 Mbaud | 
| Interface Cycle Time | ≥ 1 ms | 
| Programming Functions | Resolution, gearing factor (physical resolution) , velocity scaling + filter, preset (zero point), counting direction, limit switches , node number, teach-in, diagnosis | 
| Outputs | |
| Output Driver | Profibus Data Interface, galvanically isolated via opto-couplers | 
| Electrical Data | |
| Supply Voltage | 10 – 30 VDC | 
| Current Consumption | ≤ 115 mA @ 10 V DC, ≤ 50 mA @ 30 V DC | 
| Power Consumption | ≤ 1.5 W | 
| Start-Up Time | < 1 s | 
| Reverse Polarity Protection | Yes | 
| Short Circuit Protection | Yes | 
| EMC: Emitted Interference | DIN EN 61000-6-4 | 
| EMC: Noise Immunity | DIN EN 61000-6-2 | 
| MTTF | 13.5 years @ 40 °C | 
| Sensor | |
| Technology | Optical | 
| Resolution Singleturn | 12 bit | 
| Resolution Multiturn | 12 bit | 
| Multiturn Technology | Mechanical Gearing (no Battery) | 
| Accuracy (INL) | ±0.0220° (14 – 16 bit), ±0.0439° (≤13 bit) | 
| Code | Binary | 
| Environmental Specifications | |
| Protection Class (Shaft) | IP65 | 
| Protection Class (Housing) | IP66/IP67 | 
| Operating Temperature | -40 °C (-40 °F) – +85 °C (+185 °F) | 
| Storage Temperature | -40 °C (-40 °F) – +85 °C (+185 °F) | 
| Humidity | 98% RH, no condensation | 
| Mechanical Data | |
| Connection Cap Material | Aluminum | 
| Housing Material | Steel | 
| Housing Coating | Wet coating (RAL 9006 White Aluminium) + Cathodic corrosion protection (>720 h salt spay resistance) | 
| Flange Type | Clamp, ø 58 mm (C) | 
| Flange Material | Aluminum | 
| Shaft Type | Solid, Single Flat, Length = 20 mm | 
| Shaft Diameter | ø 10 mm (0.39″) | 
| Shaft Material | Stainless Steel V2A (1.4305, 303) | 
| Max. Shaft Load | Axial 40 N, Radial 110 N | 
| Minimum Mechanical Lifetime (10^8 revolutions with Fa/Fr) | 430 (20 N / 40 N), 150 (40 N / 60 N), 100 (40 N / 80 N), 55 (40 N / 110 N) | 
| Rotor Inertia | ≤ 30 gcm² [≤ 0.17 oz-in²] | 
| Friction Torque | ≤ 3 Ncm @ 20 °C (4.2 oz-in @ 68 °F) | 
| Max. Permissible Mechanical Speed | ≤ 12000 1/min | 
| Shock Resistance | ≤ 100 g (half sine 6 ms, EN 60068-2-27) | 
| Permanent Shock Resistance | ≤ 10 g (half sine 16 ms, EN 60068-2-29) | 
| Vibration Resistance | ≤ 10 g (10 Hz – 1000 Hz, EN 60068-2-6) | 
| Length | 80,5 mm (3.17″) | 
| Weight | 475 g (1.05 lb) | 
| Electrical Connection | |
| Connection Orientation | Radial | 
| Connection Type | 3 x Cable Gland | 
| Connection Cap Type | Removable for easy replacing encoder without new installation of cable, Rotary switches with visible node number, No active components, Terminal resistor switch cut the outgoing bus too, Big spring clips | 
| Product Life Cycle | |
| Product Life Cycle | Established | 
| Approval | CE + cULus listed, Industrial Control Equipment | 
|  | |
| Connection Plan | |
| SIGNAL | PIN NUMBER | 
| Bus line B (Bus in) | B | 
| Bus line A (Bus in) | A | 
| GND | − | 
| Power Supply | + | 
| Bus line B (Bus out) | B | 
| Bus line A (Bus out) | A | 
| GND | − | 
| Power Supply | + | 
Connector-View on Encoder